Fire Resistance

Resolite manufactures most of their fiberglass reinforced polymer panels with a fire rated resin system. In fact, Resolite developed and fabricated the first fire retardant FRP panel in 1964. Since then, Resolite has continually been in the forefront of supplying FRP panels in fire retardant resin systems.

Resolite's Tred-Safe, FS25A, CRFS25A, and RFM panels are examples of the highest quality fire retardant panel systems available. These product types are fabricated using an isophthalic, halogenated polyester resin with neopentyl glycol, acrylic modification and UV stabilizers. Each has demonstrated a flame spread rating of 25 or less when tested in accordance with ASTM E 84.

Resolite RFM panels have also been approved by Factory Mutual since they have passed the 25' and 50' full scale Corner Tests. In accordance with FM standard 4880, Resolite RFM panels have been approved for unrestricted use as a wall, roof or ceiling without height limitations or sprinkler protection. Resolite RFM 11, RFM 14 and RFM 17 panels have also passed ASTM E 108 achieving a Class B burning bran rating with a 3 in 12 roof slope.

The following guide illustrates Resolite's various fire retardant products, panel types, ratings and approvals. Please note that Resolite also manufactures Acryloy and CR-Acryloy non-fire retardant panel systems.

Product Type Panel Type Surface Burning Characteristics Approval/
Listings
Building Code Classification
Flame Spread1,5 Smoke Developed Flame Spread1,5 Rate of Burn6
Tred-Safe 1645 25 >450 UL 1, I, or A CC1
FS25A & CRFS25A 1440
1430
25
25
>450
>450
UL
UL
1, I, or A CC1
FS25A & CRFS25A 1240
1040
840
25
25
25
<450
<450
<450
UL
UL
UL
1, I, or A CC1
FS25A & CRFS25A 1230
1030
830
25
25
25
500
<450
<450
UL
UL
UL
1, I, or A CC1
RFM 17
14
11
15
15
15
<250
<250
<250
FMRC
FMRC
FMRC
1, I, or A CC1
Acryloy &
CR-Acryloy
Non-fire rated general purpose resin system ICBO Report #5048   CC2
NOTES:
  1. Resolite advises that the numerical flame spread classification is not intended to reflect hazards presented by this or any other material under actual fire conditions.
  2. UL - Underwriters Laboratories, Inc.
  3. FMRC - Factory Mutual Research Center
  4. ICBO - International Conference of Building Officials
  5. In accordance with ASTM E84/UL723, NFPA 165
  6. In accordance with ASTM D635
 

Code Compliance

Resolite fire rated FRP panels are manufactured under rigorous standards and meet many code compliance criteria. Resolite FRP panels are listed or approved under the following classifications. For additional information, please contact Resolite Customer Service or your Resolite Sales Representative.

UNDERWRITERS LABORATORIES LISTINGS

Fire Rating

Resolite fire rated product types FS25A, CRFS25A and Tred-Safe have achieved a UL Flame Spread Classification of 25 in accordance with the Steiner Tunnel Test, ASTM E 84 (UL 723).

INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS APPROVAL

ICBO Panel Listing

Resolite Acryloy fiberglass reinforced polymer panels type 720, 840 and 1240 comply with Section 217 of the Uniform Building Code as approved plastics.

FACTORY MUTUAL APPROVALS

Factory Mutual Approved Fire Rating

Resolite RFM panels have passed the 25' and 50' full scale Corner Test. In accordance with Factory Mutual Standard 4880, Resolite RFM panels have been approved for unrestricted use as a wall, roof or ceiling panel without height limitations or sprinkler protection. See above for listing.

 

Factory Mutual Approved Wind Uplift

Resolite RFM panels have passed the Factory Mutual Wind Uplift Tests and have achieved the following I-90 Classifications.

 
Profile Panel Type Class Span
7.2 x 1.5"
7.2D x 1.75"
7 x 1.5"
RFM 17, 14 I-90 6'6"
7.2 x 1.5"
7.2D x 1.75"
7 x 1.5"
RFM 11 I-90 5'0"
4.2 x 1-1/16" RFM 17, 14 I-90 5'3"

Factory Mutual Approved Insulated Panel System

Resolite RFM panels were tested as part of an insulated panel system and found to meet the FMRC Class 4453 / 4420 approval requirements for the RFM Insulated Wall and Roof / Ceiling Panel System.

 

Return to Roofing & Siding Panels


                    SEND ME MORE Resolite INFORMATION

Mr. Necktie
Email:*            
Name:*             
Company*:          
Address:*          
City, State, Zip:* 
Country:           
Voice Phone:*      
Fax Phone:         
     
Note:*

*Required information
  Press to send your message.

Press to clear the form and start over.



Return
To MAIN

Site
Map
Search
Me
Return To
Linecard
Sales
Terms
Contact
Me